>Flanged End Valve Installation<
After determining that the valve is in good condition,
attention should be given to the flange face. Dents and
heavy scratches should be repaired. Do not install
damaged valves.
Conbraco’s Cast Iron Ball valves may be installed in any
position using standard pipe fitting practices. Special
considerations are required when bolting cast iron
valves to steel flanges. When Class 125 CI valves are
to be bolted to Class 150 steel flanges, the steel flanges
shall be flat faced. Due to the brittle nature of cast iron,
consideration should also be given to proper piping
alignment.